  • Optical fiber : G.652D
  • Strength member : FRP*2
  • Water blocking type: Water blocking yarn
  • Rip rod: 1pcs 2000D
  • Jacket : HDPE
  • Span: 80m,100m,120m
  • Product Detail

    Product Tags

    The ASU fiber optic cable offered by GDTX are designed, manufactured and tested according to the standards as follows:

    ITU-T G.652.D Characteristics of a single-mode optical fiber
    IEC 60794- 1- 1 Optical fibre cables-part 2: Generic specification-General
    IEC 60794- 1-21 Optical  fiber  cables-  part1-21-Generic  specification-Basic  optical  cable  test procedure-Mechanical test methods
    IEC 60794- 1-22 Optical  fiber  cables-  part1-22-Generic  specification-Basic  optical  cable  test procedure-Environmental test methods
    IEC 60794-4- 20 Optical fibre cables-part 3- 10: Outdoor cables - Family specification for self-supporting aerial telecommunication cables
    IEC 60794-4 Optical fibre cables-Part 4: Sectional specification-Aerial optical cables along electrical power line

    Optical fibre cables supplied in compliance with this specifications is capable to withstand the typical service condition for a period of twenty-five (25) years without detriment to the operation characteristics of the cable.

    Item

    Value

    Operation temperature

    -40 ºC~+60 ºC

    Installation temperature

    -20 ºC~+60 ºC

    Storage temperature

    -25 ºC~+70 ºC

    Static bending radius

    10 times the cable diameter

    Dynamic bending radius

    20 times the cable diameter

    Technical Characteristics

    1.The unique second coating and stranding technology provide the fiber with enough space and bending endurance, which ensure good optical property of the fiber in the cable

    2.Accurate process control ensures good mechanical and temperature performance

    3.High quality raw material guarantees the long service life of cable

    Cross Section of Cable

    ASU fiber optic cable

    Fibre and Loose Tube Identification (TIA-EIA 598-B)

     

    Construction and Parameter Items

    Descriptions

    Optical fiber (G.652D) MFD1310nm):9.2±0.4umColored1310nm≤0.35 dB/km

    1550nm≤0.22 dB/km

     

    6F

    12F

    Loose tube Fibers per tube

    6

    12

    Fiber Color

    Fibre Color code

    Diameter (±0.1mmmm)

    2.0

    2.0

    Tube color

    Natural

    Natural

    Strength member  size (±0.05mm)

    2.0mmFRP*2

    2.0mmFRP*2

    Water blocking material

    Water blocking yarn

    Outer sheath Material

    Black PE

    Thickness±0.2mm

    Nominal: 1.2mm

    Rip cord

    Red  1pcs 2000D

    Cable nominal diameter (mm

    6.6

    6.6

    Cable approx. weight (±3kg/km)

    42

    42

    Minimum Bending radius Dynamic

    20 times of cable diameter

    Temperature range  Operation

    -10℃~+60℃

    PACKING Length

    3KM/DRUM

    Size

    Wrapper sheet thickness  1.5MMOD*W=780*550mm (include wrapper sheet)

    Test on tensile strength Short term and long term

    1min 1000N/400N @1550nm  Fibre strain<0.3%   Additional attenuation0.1dB

    Crush  

    1min  1000N @1550nm  Additional attenuation0.1dB

    Print Marking type

     Ink Jet marking

       

    Main mechanical & environmental characteristics test

    1.Tensile Strength IEC 794-1-E1   

    2.Crush Test IEC 60794-1-E3      

    3.Impact Test IEC 60794-1-E4

    4.Repeated Bending IEC 60794-1-E6

    5.Torsion IEC 60794-1-E7

    6.Water Penetration IEC 60794-1-F5B

    7.Temperature Cycling IEC 60794-1-F1

    8.Compound Flow IEC 60794-1-E14

    9.Sheath High Voltage Test

    Cable and Length Marking

    The sheath shall be marked with white characters at intervals of one meter with following

    information. Other marking is also available if requested by customer.

    1) Name of the manufacture: GDTX

    1) Year of the manufacturer: 2022

    2) CABLE TYPE:ADSS 100M SPAN

    3) Fiber type and counts: 24G652D 

    4) Length marking in one meter intervals: example: 0001 m, 0002m.

    Reel Length

    Standard reel length: 2/3/4 km/reel, other length is also available.